• PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
  • PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
  • PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.

PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.

Type: Professional Amplifier
Usage: Hi-Fi, AV, KTV System
Used For: Professional
Tube Type: IC Amplifier
Function: Pre-amplifier, 24V Relay Generator
Sound Channel: 2.1
Samples:
US$ 113/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
to see all verified strength labels (21)

Basic Info.

Model NO.
FTD-24RO
Output Number
8
Voltage
AC 220V
Element Number
Monoamplifier
Conductive Mode
AB
Control Channels
CH1 to CH10
Control Input
1 Set of Inputs CH1~CH10
Control Output
1 Set of Outputs CH1~CH10
Trigger
Low Level 0V or Short Circuit Signal
Output Voltage
DC24V 1A for Each Channel CH1 ~ CH10
Transport Package
Carton
Specification
520*435*88(mm)
Trademark
FTD
Origin
China
HS Code
9520909090
Production Capacity
3000/Month

Product Description

10 Channel 24V Relay Generator
FTD-24RO

PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.


FEATURES:
 
  • 10-channel 24V relay output for use in a public address system
  • 24V relay generator to provide power for volume control override in case of emergency.
  • Activated by a 10- channel input, the input alarm signals control the 24V power source outputs, thus forcefully override the PA system.
  • Two way of alarm input by 0V signal or short circuit signal
  • LED indicator for 10 channel power output monitor
SPECIFICATIONS:
 
Model FTD-24RO
Description 24V Relay Panel
Control Channels CH1 to CH10
Control Input 1 Set of Inputs CH1~CH10
Control Output 1 Set of outputs CH1~CH10
Trigger Low level 0V or short circuit signal
Output Voltage DC24V 1A for each channel CH1 ~ CH10
Indicator CH1 to CH10
Protection AC FUSE 6A 1
Power Supply AC220V, 50-60Hz
Power Consumption 20-300W
Dimension 520×435×88(mm)
Weight 8.8kg
 
PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
Guangzhou FTD Audio Limited is a leading manufacturer of Public Address System and Conference System in China, We are focus on R&D and our Professional R&D team already 15 years′ experience on Audio field. FTD audio will offer the professional products and
service to each of partner and do a win win business with our partners!
Our main products are Public address system ,EVAC system, IP PA system ,conference system ,PA amplifier and PA speaker.These
system are all designed and produced by our engineer. We are accept OEM,ODM order.


PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.

Exhibition:

 
PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.

Certifications:
 
PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.

PA System Emergency 24V Replay Outout, Auto 24V Reply to Volume Control to Override Bgm System in Case of Fire Alarm.
Deliver time:

15-20 Days after getting bank slip.

Warranty: 

One year warranty after sales. if any problem happened under warranty , you can return to us and fix it.

Why choose us:

1. More than 15 years Public address system experience , with top R&D team can accept OEM and ODM order for our customers.
2. Stable quality with good quality control, quality is our life.
3. 7*24 hours quick response for technology support.
4. Various PA system product for one shop purchase.
6. System solution designed can be offered base on requirement.
7. Reasonable price for a win win business .

FAQ:

1. Are you manufacturer?
Yes, we are public address system manufacturer located in Guangzhou, China.
Welcome to visit our factory.

2. Is sample order available? Is free sample available?
Firstly, sample order is available. Secondly, for new clients, we will return the sample fee after big order placed.

3. What's your warranty period?
Our warranty period is 12 months for speaker. 

4. What's your payment terms?
We accept Western Union and TT. 30% deposit in advance, balance 70% before shipment.

5. Where is your main market?
Customers are mainly from Europe, Middle East and South Asia.

6. How many days do you need to prepare for the goods?
It takes 30 working days for large order.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now